WDF 2460011 - Invalid object name '@OE_USERINFO' error may occur in add-on installation while migrating from SAP Intercompany solution to Walldorf Intercompany

WDF 2460011 - Invalid object name '@OE_USERINFO' error may occur in add-on installation while migrating from SAP Intercompany solution to Walldorf Intercompany

Symptom

Invalid object name '@OE_USERINFO' error may occur in add-on installation while migrating from SAP Intercompany Solution to Walldorf Intercompany

Reproducing the issue
Prerequisites:

You are using Walldorf Intercompany Add-On  Version 46.0.

Scenario:

The following error may occur in add-on installation while migrating from the SAP Intercompany Solution to the Walldorf Intercompany:
1). [Microsoft][ODBC Driver 17 for SQL Server][SQL Server]Invalid object name '@OE_USERINFO'
2). [Microsoft][ODBC Driver 17 for SQL Server][SQL Server] Statement(s) could not be prepared.


Expected Result:

Walldorf Intercompany addon is installed and connected successfully.

Actual Result:

Walldorf Intercompany Add-on fails to connect with Invalid object name '@OE_USERINFO' error.

Workaround:

Follow the below steps to fix the above issue:
1. Go to Tools-->User Defined Windows-->CTX_CONF
2. Remove the row "CTX_IC_InterCompany" from CTX_CONF table
3. Install the Walldorf Intercompany Add-On
 
Solution

The issue described above will be fixed in the Walldorf Intercompany integration solution Version 47 for SAP Business One, and higher versions.

Product
Product or Product Version
B1 INTERCOMPANY INTEGRATION 2.0
SAP B1 10.0 FOR SAP HANA
SAP B1 9.3 FOR SAP HANA
SAP BUSINESS ONE 10.0
SAP BUSINESS ONE 9.3

This document refers to : 
WDF 2470001 - Overview Note for Intercompany integration solution 2.0 Version 47 for SAP Business One